Sizing Footings with IRC 2024 Table R403.1(1): Soil, Snow Load, and the 32-Foot Rule

How to read IRC 2024 Table R403.1(1) for footing width and thickness: soil bearing from Table R401.4.1(1), the snow or live load row, interpolation and the 32-ft footnotes.

Code references covered

IRC 2024 Section R403.1.1 · IRC 2024 Table R403.1(1) · IRC 2024 Tables R403.1(2), R403.1(3) · IRC 2024 Section R401.4.1 · IRC 2024 Table R401.4.1(1) · IRC 2024 Sections R403.1.4, R403.1.4.1

Checked against the 2024 IRC (Second Printing) on 2026-11-14. Confirm the edition your exam and jurisdiction use, and any local amendments.

Footing size is a classic B1 table question: given the soil, the snow load, the number of stories and the foundation type, how wide and how thick must the concrete footing be? IRC 2024 Section R403.1.1 points you to Table R403.1(1) and its companion tables. This guide shows how to read the table, how to use its notes, and where the minimums come from.

Step 1: Pick the right table

Section R403.1.1 refers to three footing tables. They look alike, so check the title first:

  • Table R403.1(1) — light-frame construction (the typical wood-framed house).
  • Table R403.1(2) — light-frame construction with brick veneer or lath and plaster. These walls are heavier, so the footings come out wider.
  • Table R403.1(3) — cast-in-place concrete or partially grouted masonry wall construction.

Every cell in these tables is in inches and reads width × thickness. A cell of “16 × 6” means a footing 16 inches wide and 6 inches thick.

Step 2: Find the soil bearing value (the column)

The columns are the load-bearing value of the soil, from 1,500 to 4,000 pounds per square foot. If there is no soils report, Section R401.4.1 says the presumptive values in Table R401.4.1(1) are assumed. A few you will see often: sandy gravel and gravel are 3,000 psf; sand, silty sand and clayey sand are 2,000 psf; and the clay and silt group is 1,500 psf. If the building official determines that soil weaker than 1,500 psf is likely on the site, a note to that table requires a soils investigation.

Step 3: Find the load row and the building row

The rows are grouped by ground snow load or roof live load. The first group is labeled for a 20 psf roof live load or 25 psf ground snow load; the others are 30, 50 and 70 psf. Within each group, pick the row for the number of stories (1, 2 or 3) and the foundation type: slab-on-grade, crawl space or basement.

The ground snow load usually comes from the question or from the jurisdiction's entries in Table R301.2. Note a only allows interpolation between soil columns. When a snow load falls between two rows, the conservative reading is the next higher row.

Worked example 1 — same house, two soils

A two-story house over a crawl space, 30 psf ground snow load, light-frame walls. On silty sand (2,000 psf from Table R401.4.1(1)), Table R403.1(1) gives 12 × 6. Move the same house to a clay site (1,500 psf) and the cell becomes 16 × 6. The soil column alone added 4 inches of width.

Step 4: Use the table notes

Table R403.1(1) has four lettered notes, and B1 questions like to test them.

Note a — interpolation

Linear interpolation of footing width is permitted between the listed soil bearing values. Extrapolation beyond the table is not.

Worked example 2 — interpolating between soil columns

A two-story house with a basement, 30 psf ground snow load. A soils report gives 1,750 psf. The table shows 19 × 6 at 1,500 psf and 14 × 6 at 2,000 psf. Halfway between the columns, the width is halfway between 19 and 14: 16.5 inches, with a 6-inch thickness (both cells show 6).

Note b — what the table assumes

The table is built on a set of assumptions, including a 32-foot building width, 9-foot walls, an 8-foot basement wall, listed dead loads for the roof, floors and walls, and floor live loads of 40 psf on the first floor and 30 psf above. It also assumes a clear-span roof and an interior bearing wall or beam at each floor. If a question changes one of these, look for a note that adjusts for it.

Notes c and d — wider or narrower buildings

Building width here is measured perpendicular to the wall footing. For each 4 feet over 32 feet, note c requires the footing to grow by 2 inches in width and 1 inch in depth. For each 4 feet under 32 feet, note d permits a 2-inch decrease in width and a 1-inch decrease in depth — but never below 12 inches wide and 6 inches deep.

Worked example 3 — a 40-foot-wide house

Same two-story house with a basement, 30 psf snow, 1,500 psf soil: the table gives 19 × 6. The house is 40 feet wide, 8 feet more than the table assumes. That is two 4-foot steps, so add 4 inches of width and 2 inches of depth: 23 × 8.

Worked example 4 — a 28-foot-wide house

A two-story house over a crawl space, 30 psf snow, 1,500 psf soil: the table gives 16 × 6. At 28 feet wide, the house is one 4-foot step narrower. Width may drop to 14 inches, but depth cannot drop below the 6-inch minimum, so the result is 14 × 6.

The minimums that apply to every footing

  • Section R403.1.1 — never less than 12 inches wide and 6 inches thick. The footing projection beyond the wall must be at least 2 inches and may not exceed the footing thickness.
  • Section R403.1.4 — exterior footings go at least 12 inches below undisturbed ground.
  • Section R403.1.4.1 — frost protection by one of the listed methods, such as extending below the frost line from Table R301.2 or using a frost-protected shallow foundation (Section R403.3).

Keep thickness and depth separate in your head. The “6” in a table cell is the concrete thickness of the footing itself. How deep the bottom of the footing sits below grade is a different rule (R403.1.4 and frost depth).

Common mistakes

  1. Using Table R403.1(1) for a brick-veneered house instead of Table R403.1(2).
  2. Reading the 25 psf snow row when the question gives a 30 psf ground snow load.
  3. Extrapolating below 1,500 psf or above 4,000 psf — note a does not allow it.
  4. Forgetting notes c and d when the question states a building width other than 32 feet.
  5. Taking the table value without checking the 12 × 6 minimums after a note d reduction.

For how footings fit into the exam weights, see the B1 exam overview. The framing those footings carry is covered in wall framing basics.

For the exact code language, read the sections on the official ICC Digital Codes site. We cite section identifiers and explain the logic in our own words — always confirm the current text and any local amendments there.

Want to practice this topic under exam conditions?

B1 practice questions built on the 2024 IRC are in development. Join the waitlist and we'll email you when they open.

Free. We'll email you when B1 practice opens.

Also preparing for another exam? Try 10 free M1 questions · Try 10 free P1 questions

Related guides

Frequently asked questions

What building width is Table R403.1(1) based on?
Note b of Table R403.1(1) says the table assumes a 32-foot building width, along with set wall heights, dead loads and floor live loads. Notes c and d adjust the footing for buildings wider or narrower than 32 feet.
Can I interpolate between soil bearing columns in Table R403.1(1)?
Yes. Note a permits linear interpolation of footing width between the listed soil bearing pressures, but extrapolation beyond the table is not permitted.
What soil bearing value do I use if there is no soils report?
Section R401.4.1 says that in lieu of a complete geotechnical evaluation, the presumptive values in Table R401.4.1(1) are assumed. For example, sand, silty sand and clayey sand are 2,000 psf, and the clay and silt group is 1,500 psf.