The ICC B1 Exam: Format, Content Areas, and How the 2024 IRC Is Organized
A plain-language overview of the ICC B1 residential building inspector exam: 60 questions, 2 hours, open book, seven weighted content areas, and a 2024 IRC chapter map.
Code references covered
IRC 2024 Chapters 1–11 · IRC 2024 Section R101.2 · IRC 2024 Table R301.2 · IRC 2024 Sections R310, R311, R318–R321, R324
Checked against the 2024 IRC (Second Printing) on 2026-11-14. Confirm the edition your exam and jurisdiction use, and any local amendments.
The ICC B1 is the certification exam for residential building inspectors. If you inspect footings, foundations, framing, wall coverings, roofs, stairs and egress in houses and townhouses, this is the credential that shows you can apply the residential building code. This guide covers how the exam is put together, how its seven content areas are weighted, and how the 2024 IRC is laid out so you can find B1 answers fast.
The format in one paragraph
The B1 has 60 questions and a 2-hour time limit, so you have about two minutes per question. It is open book. Our guides are built on the 2024 International Residential Code (IRC); before you schedule, confirm on ICC's exam catalog which code edition and references your B1 exam allows, because that is what the answers are graded against.
The exam covers the buildings the IRC itself covers. IRC 2024 Section R101.2 scopes the code to detached one- and two-family dwellings and townhouses not more than three stories above grade plane, plus their accessory structures. Anything bigger belongs to a different code and a different exam.
The seven content areas and their weights
ICC divides the B1 into seven major content areas. The question counts below are only our arithmetic — what each percentage would mean on a 60-question form — not official quotas, and they do not add to exactly 60 because of rounding.
| Content area | Weight | ≈ Questions (our estimate) | Where it mostly lives in the 2024 IRC |
|---|---|---|---|
| Code Administration | about 4%* | 2–4 | Chapter 1 (permits, inspections, notices) |
| Building Planning | 8% | 5 | Chapter 3 (fire separation R302, room areas R312, ceiling height R313, light and ventilation R325) |
| Footings and Foundations | 16% | 10 | Chapter 4 |
| Floor Construction | 14% | 8 | Chapter 5, plus crawl spaces (R408) and draftstopping (R302.12) |
| Wall Construction and Coverings | 27% | 16 | Chapters 6 and 7, plus fireblocking (R302.11) |
| Roof/Ceiling Construction | 14% | 8 | Chapters 8, 9 and 10, plus attic insulation in Chapter 11 |
| Public Safety and Special Construction | 17% | 10 | Chapter 3 (egress, stairs, guards, smoke alarms, glazing) and decks (R507) |
* ICC's published outline is not consistent about the Code Administration weight, so we show it as a small share of about 4% and will update this page once it is confirmed. Either way it is the smallest area on the exam.
Two things stand out. Wall Construction and Coverings alone is more than a quarter of the exam. And the four structural areas — foundations, floors, walls and roofs — add up to roughly 70%. Most of those points come from tables: footing sizes, stud spacing, joist and rafter spans, fastening schedules. That is good news, because table lookups are a skill you can drill.
How the 2024 IRC is organized for the B1
The building provisions are in Chapters 1 through 11. Each section number starts with “R” (or “N” in Chapter 11), and the first digit or two after the letter is the chapter: R403 is in Chapter 4, R602 in Chapter 6, R806 in Chapter 8. Tables are named after their section, so Table R602.3(5) belongs to Section R602.3.
| Chapter | Title | What B1 candidates look up there |
|---|---|---|
| 1 | Scope and Administration | Permits and exemptions, inspections, stop work orders, certificate of occupancy |
| 2 | Definitions | Grade floor opening, fire separation distance, story, habitable space |
| 3 | Building Planning | Design criteria, fire separation, egress, stairs, guards, smoke alarms, glazing |
| 4 | Foundations | Soil bearing, footing size and depth, foundation walls, crawl spaces |
| 5 | Floors | Joist spans, bearing, notching, decks (R507), subfloor, slabs |
| 6 | Wall Construction | Studs, top plates, headers, cutting limits, wall bracing |
| 7 | Wall Covering | Gypsum board, water-resistive barrier, flashing, siding, veneer, stucco |
| 8 | Roof-Ceiling Construction | Rafter and ceiling joist spans, trusses, sheathing, attic ventilation and access |
| 9 | Roof Assemblies | Roof coverings, underlayment, ice barrier, flashing, reroofing |
| 10 | Chimneys and Fireplaces | Firebox, hearth extension, clearances, chimney termination |
| 11 | Energy Efficiency | Insulation levels and installation details that inspectors check |
Watch the 2024 renumbering in Chapter 3
Chapter 3 was heavily renumbered in the 2024 IRC. The preface of the code includes a relocation table, and several of the moves hit core B1 topics. If your notes, flash cards or older prep books use 2021 numbers, translate them before you study:
| Topic | 2021 IRC | 2024 IRC |
|---|---|---|
| Means of egress and stairways | R311 | R318 |
| Emergency escape and rescue openings | R310 | R319 |
| Handrails | R311.7.8.1–R311.7.8.6 | R320 |
| Guards and window fall protection | R312 | R321 |
| Glazing (safety glazing) | R308 | R324 |
| Smoke alarms | R314 | R310 |
| Carbon monoxide alarms | R315 | R311 |
The trap goes both ways: in 2024, R308 is site address and R310 is smoke alarms, so an old reference can send you to a real section about something else entirely.
Table R301.2 is filled in locally
Many B1 rules depend on climate and site data — ground snow load, frost line depth, weathering, whether an ice barrier is required. Those values live in Table R301.2, which each jurisdiction fills in when it adopts the code. On the exam, expect the question to give you that value. Do not assume a number from your own area.
A study plan that matches the exam
1. Learn the map first
Spend your first sessions learning which chapter holds which topic, using the table above, until you can open the book to the right chapter on the first try.
2. Drill the big table families
Work through the lookups that carry the most weight: footing sizes from Table R403.1(1), stud size, spacing and cutting limits, and floor joist and rafter span tables. For each, practice reading the table notes, because they change answers.
3. Learn the life-safety numbers by section
Public Safety is 17% and full of specific dimensions. Our guide to escape openings, stairs, handrails and guards walks through them under the 2024 numbering, and the attic ventilation and shingle guide covers two frequent roof topics.
4. Practice with the book open, then under the clock
For every practice question, find the section that answers it and read its exceptions, even when you got it right. In the last phase, work in timed blocks so that two minutes per question feels normal.
For the exact code language, read the sections on the official ICC Digital Codes site. We cite section identifiers and explain the logic in our own words — always confirm the current text and any local amendments there.
Want to practice this topic under exam conditions?
B1 practice questions built on the 2024 IRC are in development. Join the waitlist and we'll email you when they open.
Also preparing for another exam? Try 10 free M1 questions · Try 10 free P1 questions
Related guides
Sizing Footings with IRC 2024 Table R403.1(1): Soil, Snow Load, and the 32-Foot Rule
Pick the right row and column, interpolate, and adjust for building width with notes c and d.
Wall Framing Basics: Stud Size and Spacing, Top Plates, Notching and Boring (IRC 2024)
Read Table R602.3(5), check top plates, and apply the 25/40/60 percent stud cutting limits.
Escape Openings, Stairs, Handrails and Guards: R318–R321 in the 2024 IRC
Opening size, sill height and area wells, then stair geometry, handrails and guards.
Frequently asked questions
- How many questions are on the ICC B1 exam and how long is it?
- The B1 exam has 60 questions and a 2-hour time limit, which works out to about two minutes per question. It is open book.
- Which B1 content area carries the most weight?
- Wall Construction and Coverings is the largest area at 27%. Public Safety and Special Construction is 17%, Footings and Foundations 16%, Floor Construction and Roof/Ceiling Construction 14% each, and Building Planning 8%. Code Administration is a small share, about 4%.
- Why do my IRC section numbers for stairs and egress windows not match older study notes?
- Chapter 3 was renumbered in the 2024 IRC. Means of egress and stairways moved from R311 to R318, emergency escape and rescue openings from R310 to R319, guards from R312 to R321, safety glazing from R308 to R324, and handrails now have their own Section R320.